Nick Ramirez is a software developer living in Columbus, Ohio. As a believer that deployment shouldn't be terrifying, he has become a big fan of technologies such as WiX. His other related interests include build automation, software architecture, and playing Minecraft. Nick lives with his wife and two cats.
Read more about Nicholas Matthew Ramirez

Right arrow

Referencing the output of a .NET console application in a WiX project by using a preprocessor variable


After setting up our WiX project, the first thing we'll probably want to do is package up the files that we plan to install. Since we're working in Visual Studio, we'll likely want to include the output of other projects such as the .exe file that's created from a console application project. At first, we could try hardcoding the path to the file:

<Component Id="cmpMyConsoleAppEXE" 
  Guid="{882DB6AA-1363-4724-8C43-2950E7ABECD4}">
  <File Source="..\MyConsoleApp\bin\Debug\MyConsoleApp.exe" />
</Component>

Although this works, it's a bit brittle and will break if the path to the file changes. Instead, we can use a preprocessor variable to store the path and allow Visual Studio to keep it up-to-date through the power of project references. In this recipe, we'll reference a console application's output and use a preprocessor variable to include that output in our installer.

Getting ready

To prepare for this recipe, create a new WiX setup project and name it ConsoleAppInstaller.

How to do it…

Use a preprocessor variable to get the path to a project's output with the following steps:

  1. Add a new C# console application to the same solution as the ConsoleAppInstaller setup project by right-clicking on the solution in Solution Explorer, going to Add | New Project… | Visual C# | Console Application and naming it TestApplication. The name matters as we'll be referencing it later:

  2. Within the setup project, add a reference to TestApplication by right-clicking on the References node in Solution Explorer, choosing Add Reference..., and finding TestApplication under the Projects tab. Click on Add and then on OK:

  3. Within the setup project, open Product.wxs and replace the ComponentGroup markup inside the last fragment with the following code:

    <ComponentGroup Id="ProductComponents" 
      Directory="INSTALLFOLDER">
      <Component Id="cmpTestApplicationEXE" 
        Guid="{6E2A6370-4784-4CF3-B42B-AA2D29EA5B1B}">
        <File Source="$(var.TestApplication.TargetDir)TestApplication.exe" />
      </Component>
    </ComponentGroup>
  4. Build the project and TestApplication.exe will be included in the MSI file. Note that you must set the EmbedCab attribute on the MediaTemplate element to yes to include the CAB file that WiX creates, which is where our .exe file is stored, inside the MSI. Also, this example assumes that TestApplication.exe is the only file you'd like to include in the installer. Other files, such as DLLs, can be included in the same way though.

How it works…

When we referenced the C# console application within the WiX setup project, the preprocessor variable $(var.[ProjectName].TargetDir) was made available to us, where ProjectName in this case is TestApplication. TargetDir points to the output directory of the console application project where our compiled TestApplication.exe file can be found.

Other preprocessor variables are also made available. For example, $(var.[ProjectName].TargetFileName) gives you the name of the compiled application, which for us would be TestApplication.exe. A full list of these variables can be found at http://wixtoolset.org/documentation/manual/v3/votive/votive_project_references.html.

Another benefit of referencing the console application project in this way is that it ensures it is compiled before our setup project is. This way, our installer always includes the most up-to-date version of the application.

Note

The GUID used for the Guid attribute on the Component element in this example can be any GUID, not just the one listed. You can generate a new one in Visual Studio by navigating to Tools | Create GUID. Use Registry Format as the GUID's format. More information can be found at http://wixtoolset.org/documentation/manual/v3/howtos/general/generate_guids.html.

You can also set the Guid attribute to an asterisk (*) or omit it altogether and WiX will set the GUID for you. You should choose your own if you plan on authoring a patch file for the application in the future or if the contents of Component don't contain an element that can be marked as a KeyPath element.

Previous PageNext Page
You have been reading a chapter from
WiX Cookbook
Published in: Jan 2015Publisher: ISBN-13: 9781784393212
Register for a free Packt account to unlock a world of extra content!
A free Packt account unlocks extra newsletters, articles, discounted offers, and much more. Start advancing your knowledge today.
undefined
Unlock this book and the full library FREE for 7 days
Get unlimited access to 7000+ expert-authored eBooks and videos courses covering every tech area you can think of
Renews at $15.99/month. Cancel anytime

Author (1)

author image
Nicholas Matthew Ramirez

Nick Ramirez is a software developer living in Columbus, Ohio. As a believer that deployment shouldn't be terrifying, he has become a big fan of technologies such as WiX. His other related interests include build automation, software architecture, and playing Minecraft. Nick lives with his wife and two cats.
Read more about Nicholas Matthew Ramirez